Airtech USA Return to Airtech Homepage
Questions? Call Us Today!

888-222-9940

3BA1300 Vacuum/Pressure Regenerative Blower
Products > Regenerative Blowers > Model 3BA1300

 

Selection & Ordering Data - Type 3BA1300

Curve
No.
Order
No.
Hz
HP
Input
Voltage (V)
Input
Current (A)
Permissible total differential pressure2
Sound pressure level3
Weight (lbs.)
 
 
 
 
 
 
 
 
Vacuum inch H2O
Compressor
inch H2O
dB(A)
 

3~ 50/60 Hz IP55 insulation material class F

A 130

3BA1300-7AT06

50

0.34

200D... 240D

345Y...415Y

2.1D

1.2Y

-40

44

53

18

A 131

3BA1300-7AT06

60

0.39

220D... 250D

415Y...460Y

1.74D

1.0Y

-44

44

56

18

A 132

3BA1300-7AT16

50

0.54

200D... 240D

345Y...415Y

2.6D

1.5Y

-48

52

53

22

A 133

3BA1300-7AT16

60

0.67

220D... 250D

415Y...460Y

2.6D

1.5Y

-60

64

56

22

1~ 50/60 Hz IP55 with attached capacitor for continuous operation

A 132s

3BA1300-7AS15

50

0.50

115

230

5.4

2.7

-44

44

53

22

A 133s

3BA1300-7AS15

60

0.60

115

230

6.0

3.0

-52

56

56

22

 

Dimensions

3BA1300 Dimensions

Relief valve:
VC51Z (Vacuum)
PC51Z (Pressure)
 
Flter:
ATF-125-1337
(Vacuum)
 
AFS-20-125-10
(Pressure)

 

Performance Curve for Vacuum Pump

3ba1300 Vacuum Pump Chart

 

Performance Curve for Compressor

3ba1300 Compressor Chart

 

 

 


1300


Model Features

  • Cooler running, outboard bearing provides maintenance-free operation
  • Environmentally friendly oil-free technology
  • Extremely quiet operation
  • All motors are standard TEFC with Class F insulation, UL recognized, CE Compliant
  • Explosion-Proof motors available
  • Custom construction blowers are available
  • Rugged die cast aluminum construction

PDFDownload the
3BA1300 Data Sheet

Adobe Acrobat Required
286kb, PDF File

PDFDownload the 3BA Product Series
Operating & Instruction Manual

Adobe Acrobat Required
5.86Mb, PDF File

 

*Specifications subject to change without notice. Please contact factory for specification updates.