Airtech USA Return to Airtech Homepage
Questions? Call Us Today!

888-222-9940

3BA1640 Vacuum/Pressure Regenerative Blower
Products > Regenerative Blowers > Model 3BA1640

 

Selection & Ordering Data - Type 3BA1640

Curve
No.
Order
No.
Hz
HP
Input
Voltage (V)
Input
Current (A)
Permissible total differential pressure2
Sound pressure level3
Weight (lbs.)
 
 
 
 
 
 
 
 
Vacuum inch H2O
Compressor
inch H2O
dB(A)
 

3~ 50/60 Hz IP55 insulation material class F

A 260

3BA1640-7AT36

50

5.36

200D... 240D

345Y...415Y

13D

7.5Y

-60

56

74

117

A 261

3BA1640-7AT36

60

6.16

220D... 250D

415Y...460Y

15.2D

8.5Y

-40

36

78

117

A 262

3BA1640-7AT46

50

7.37

200D... 240D

345Y...415Y

23D

13.3Y

-96

104

74

161

A 263

3BA1640-7AT46

60

8.44

220D... 250D

415Y...460Y

20D

11.2Y

-84

80

78

161

A 264

3BA1640-7AT56

50

10.05

200D... 240D

345Y...415Y

29D

16.7Y

-96

128

74

189

A 265

3BA1640-7AT56

60

11.52

220D... 250D

415Y...460Y

27.5D

15Y

-108

120

78

189

 

Dimensions

3BA1640 Dimensions

Relief valve:
VC61Z (Vacuum)
PC61Z (Pressure)
 
Flter:
ATF-200-15124/1
(Vacuum)
 
AFS-30-200-10
(Pressure)

 

Performance Curve for Vacuum Pump

3ba1640 Vacuum Pump Chart

 

Performance Curve for Compressor

3ba1640 Compressor Chart

 

 

 

1640


Model Features

  • Cooler running, outboard bearing provides maintenance-free operation
  • Environmentally friendly oil-free technology
  • Extremely quiet operation
  • All motors are standard TEFC with Class F insulation, UL recognized, CE Compliant
  • Explosion-Proof motors available
  • Custom construction blowers are available
  • Rugged die cast aluminum construction

PDFDownload the
3BA1640 Data Sheet

Adobe Acrobat Required
286kb, PDF File

PDFDownload the 3BA Product Series
Operating & Instruction Manual

Adobe Acrobat Required
5.86Mb, PDF File

 

*Specifications subject to change without notice. Please contact factory for specification updates.