Airtech USA Return to Airtech Homepage
Questions? Call Us Today!

888-222-9940

3BA1930 Vacuum/Pressure Regenerative Blower
Products > Regenerative Blowers > Model 3BA1930

 

Selection & Ordering Data - Type 3BA1930

Curve
No.
Order
No.
Hz
HP
Input
Voltage (V)
Input
Current (A)
Permissible total differential pressure2
Sound pressure level3
Weight (lbs.)
 
 
 
 
 
 
 
 
Vacuum inch H2O
Compressor
inch H2O
dB(A)
 

3~ 50/60 Hz IP55 insulation material class F

A 350

3BA1930-7AT06

50

11.39

200D... 240D

345Y...415Y

33D

19.1Y

-48

44

75

268

A 351

3BA1930-7AT06

60

13.14

220D... 250D

415Y...460Y

33D

19.1Y

-32

28

80

268

A 352

3BA1930-7AT16

50

16.75

200D... 240D

345Y...415Y

48.5D

28Y

-84

76

75

298

A 353

3BA1930-7AT16

60

19.43

220D... 250D

415Y...460Y

50D

29Y

-72

64

80

298

A 354

3BA1930-7AT36

50

24.80

200D... 240D

345Y...415Y

64.5D

37Y

-124

128

75

318

A 355

3BA1930-7AT36

60

28.54

220D... 250D

415Y...460Y

68D

39Y

-120

112

80

318

 

Dimensions

3BA1930 Dimensions

Relief valve:
VC100Z (Vacuum)

PC100Z (Pressure)

 
Flter:
ATF-400-21138
(Vacuum)
 
AFS-234-400-10
(Pressure)

 

Performance Curve for Vacuum Pump

3ba1930 Vacuum Pump Chart

 

Performance Curve for Compressor

3ba1930 Compressor Chart

 

 

 

1930

Model Features

  • Cooler running, outboard bearing provides maintenance-free operation
  • Environmentally friendly oil-free technology
  • Extremely quiet operation
  • All motors are standard TEFC with Class F insulation, UL recognized, CE Compliant
  • Explosion-Proof motors available
  • Custom construction blowers are available
  • Rugged die cast aluminum construction

PDFDownload the
3BA1930 Data Sheet

Adobe Acrobat Required
286kb, PDF File

 

PDFDownload the 3BA Product Series
Operating & Instruction Manual

Adobe Acrobat Required
5.86Mb, PDF File

 

*Specifications subject to change without notice. Please contact factory for specification updates.