The AIRTECH Dual Knock-out Pot / Inlet Filter is designed to protect your vacuum pump from liquid slugs and solid debris.

Preventing entry of liquids and solid particulates into the pump will reduce pump oil / contamination, improves operating efficiency and prolongs the life of the pump.

Entrained liquid is separated in the knock-out pot by a unique baffle design. Elimination of demister pads minimizes pressure drop in the vessel.

Multi-stage separation is accomplished by the initial tangential entry of the gas stream baffle location; the particulate filter which removes solids down to 10 micron in size.


 

AT-KOP Knock Out Pot Dimensions (Inches)

Model

A

B

C

D

E

F

G

H

I

Inlet

Exhaust

Condensate

 Volume

AT-KOP-8
8
55
25
25
18
2.5
20
22.5
37
2"-150#
2"-150#
5 gal.
AT-KOP-11
10.75
61.375
25.875
35.69
18
2.5
20
22.5
40.75
3"-150#
3"-150#
10 gal.

AT-KOP


 


 
 

 




Knockout Pot Features

  • Simplistic space saver design,
       for liquid and solid separation
  •  Removable cover with V-band closure
      and T-bolts (no tools required)
  •  Carbon steel or stainless steel housing
     designed and tested for full vacuum service
  •  Self-supporting on three legs for free
       standing installation
  • Access ports for 3 level switches, sight
        glass, and various instrumentation
  •  Liquid drain valve
  •  Design pressure - Full vacuum
  •  Design temperature - 20 to +2000 °F

 

PDFDownload the AT-KOP Knock-Out Pot Brochure

Adobe Acrobat Required
70Kb, PDF File

 


 

 

 

*Specifications subject to change without notice. Please contact factory for specification updates.